Generally, this manifold arrives presterilized, and thus calibration cannot be done at time of use without compromising the sterility of the system. The statistics also demonstrate the precision of the sensor/PMAT-SHR combination. This push toward continuous manufacturing, coupled with the benefits of, single-use technology, creates demand for single-use sensors that have proven performance during long-term use. The materials used in PendoTECH single-use pressure sensors are well-characterized and highly durable polymers commonly found in other biopharmaceutical and medical device products that require long life cycles. It has a convenient DIN rail mounting design. This diagram shows sensors and monitors may be integrated into an existing plant architecture if transmission and communications functions are available. No reviews were found for PendoTECH - Single Use Pressure Sensors. For potential use in a pressure-hold/leak-test application, the contribution of the 0.003 psi ZOS can be calculated by the following example. Another challenge of incorporating single-use sensors into a GMP process is the closed nature of the bioprocess system and associated single-use manifold. %PDF-1.4 %

} ?yw*}QO>Opm*7u}Ywf=(ztpW2mJmqtXgmcYg=7aSzp.]C56W;->`[gHv:&9FufegnqV4)f]{Mf)[F/SCoabugBf;N3c!fh5!x9mdbF#VGbD`rDG%|H manufactured in a clean room in an fdaregistered, iso 13485 facility low cost polycarbonate material or caustic resistant polysulfone certificate of quality included with lot certification; individual nist calibration certificates are optional may be non-invasively tested in-place via test port convenient handheld design allows you to read pendotech single use pressure sensorst reads sensors to their specification of 0-6 psi +/- 2% of reading; 0-30 psi +/- 3% of reading. The pressure displayed on the PMAT-SHR pressure monitor was recorded at each pressure or vacuum level, and results were compared with that from the Crystal gauge. powder port, (Bronze), ULTA Prime GF and ULTA Prime CG single use capsule assemblies, Analytical Instrumentation PendoTECHs pressure sensors, which are qualified for use up to 75 psi, are compatible with PendoTECHs PressureMAT monitor/transmitter, PendoTECHs Process Control Systems or other pre-qualified third-party monitors. This is ideal for low-pressure applications, and the zero-offset stability (ZOS) is reduced to <0.003 psi, compared to 0.03 psi for the standard PMAT. =(0.003 psi 1,000 L)/(10 min 14.7 psi) Online product catalogs, news, articles, events, publications & more. In addition to being robust enough for continuous processing, PendoTECH single-use pressure sensors are accurate enough for processes requiring highly precise measurements, including leak testing. PendoTech PMAT-DPG Handheld PressureMAT Monitor for one pressure sensor. Terms The methods used to make this claim for single-use pressure sensors are shown in, terials, during a continuous process of up to, 90 days, the susceptibility of the sensor to. PendoTECH Pressure Sensors for Smaller Scale Processes. Our specialists are here to help you find the best product or part available for your application. We do not have any recommendations at this time. Privacy, Our sites:

The sensors feature PendoTECH High Accuracy Pressure (MEMS-HAP) Chips and are perfect for filtration and chromatography processes, monitoring of glass and disposable bioreactors, filling operations and more. Dedicated to the success of your entire fluid path from research to production since 1955. It is highly advantageous to be able to conduct these tests with a single-use pressure sensor, preinstalled on the bag/manifold, so that sterility is not compromised during this test. The data presented here indicate that using the PMAT-HR monitor with PendoTECH single-use pressure sensors provides excellent experimental results for high-accuracy pressure measurement in the range of 0.500 to 2.000 psi. The full test procedure and results are available by contacting PendoTECH, but an overview of the test is presented at the end of this article. The pressure sensors are very accurate in the pressure ranges typically used with flexible tubing and are qualified for use to 75 psi. Be the first to review! Our disposable pressure sensor is rugged so that can be repeatedly cleaned. Figure 2 illustrates a generic plant architecture diagram. Please try your search again later. PendoTECH's Single Use Pressure Sensors, Pressure measurement, Can be used for 1/8 inch to 1 inch ID pipes (see below for Luer connector dimensions) or sanitary flangesSignificantly reduced holdup compared to stainless steel sensors or pressure gaugesQualified use range is -7 to 75 psiCompatible with gamma raysAll materials meet USP Class VIIntegrated 12-inch cable connects to reusable display / transmitter / alarm cable via molded connectorsEach sensor is tested for quality and accuracy during the manufacturing process and rejected if it exceeds specifications (no calibration required)Manufactured in a clean room in an FDA-registered ISO 13485 facilityCan be washed and reused repeatedlyLow priceThe sensor may be autoclaved oncePolycarbonate or corrosion-resistant polysulfone (please review application note-Autoclave for disposable pressure sensors)Quality certificate included in batch certification; separate NIST calibration certificate is optionalNon-invasive in-situ testing with PressureCHECKER equipmentValidation guide is available. Re-enter your KBA number(HSN/TSN) or choose according to make and model. Figure 2. All Rights Reserved. Better accuracy and repeatability is achieved by selecting the narrowest range that meets the application DetailsConnections to the Transmitter are quick and convenient. Call or Email us and we will make sure you get the right product or part for the job.

Returning Products with Inspect & Buy label, Price includes custom duties and all other applicable taxes. Environmental XPRT is part of XPRT Media All Rights Reserved. For mid-range applications there is a Transmitter device with a 4-20mA range of 0-10 psi. There is no product in the shopping cart, buy it! These results show that group averages, measured to three decimal places, are nearly identical to the applied pressure. The sensors and monitors occupy the boxes to the left, while higher-level control systems are represented by the boxes on the right half of the diagram. Manual will be automatically added to "My Manuals", 3 Flow Meter Function in Pressuremat-PLUS (2P, 3P & 2F), Navigation in the Flow Meter Input Channel, 4 Analog Input Function in Pressuremat-PLUS (2P, 3A & 2A Only), APPENDIX B: Pendotech Single Use Pressure Sensors, APPENDIX C: Pressuremat Data Acquisition Software, APPENDIX F: Pinch Valve Box Accessory (PDKT-PVE), APPENDIX G: Using the Pressuremat with Winwedge Software, APPENDIX H: Pressuremat Smoothing Function (PV Filter), Page 4: Overview Of Pendotech Pressuremat, Page 25: Flow Meter Function In Pressuremat-Plus (2P, 3P & 2F), Page 30: Analog Input Function In Pressuremat-Plus (2P, 3A & 2A Only), Page 36: Appendix B: Pendotech Single Use Pressure Sensors, Page 37: Appendix C: Pressuremat Data Acquisition Software, Page 39: Appendix D: Panel Mount Of System, Page 41: Appendix E: Ec Declaration Of Conformity, Page 42: Appendix F: Pinch Valve Box Accessory (Pdkt-Pve), Page 44: Appendix G: Using The Pressuremat With Winwedge Software, Page 45: Appendix H: Pressuremat Smoothing Function (Pv Filter). It is also inexpensive so that can be used for single-use applications. All Rights Reserved. They are available in caustic-resistant polysulfone to withstand sanitization processes. The full test procedure and results are available by contacting PendoTECH, but an overview of the test is presented at the end of this article. Note: In summary, PendoTECH single-use sensors are robust enough to be considered for qualification in GMP processes. have been tested to withstand continuous use of up to 90 days. Stay in touch with us for the freshest products! temperature sensors monitors sensor For use in extended continuous processes, single-use sensors must be designed for single use without sacrificing performance and lifetime compared to traditional stainless-steel instruments. Sensors incorporated into a continuous processing facility must be evaluated based on process-specific user requirementssuch as required sensor lifetime, compatibility, and process accuracy requirements. bioprocess sensors adoption operations single use Leak-testing/pressure-decay on single-use systems with air is feasible by applying the ideal gas law as long as a pressure-sensing device can measure to the accuracy required for a low-pressure system, such as in single-use bioreactors and storage bags. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. One 9V battery lasts up to 14 hours. In this experiment, 30 sensors were randomly selected from three separate lots and exposed to two different levels of gamma irradiation: 27.533 kGy (low) and 4045 kGy (high). Specifications Ordering Information PT-2 Pressure sensor transmitter with 4-20mA output, 0-2 psi (0.138 bar) DIN Rail mount, 24VDC, with calibration certificate and cable, Transmitter, Sensor, Pendotech, Sensor transmitter. The averages, standard deviations, and relative standard deviations were calculated and reported for sensors grouped by lot and irradiation level. If you do not receive a response from the seller for your return request within two business days, you can submit an A-to-Z Guarantee claim. Furthermore, the data show that two typical levels of gamma irradiation make no significant difference in the accuracy or consistency of results. Each monitor has a 12 ft (3.7 m) cable to connect to the sensor. Battery operated - uses 9v battery (approximate 14 hours of power). Analytical Equipment, Neuro and Cardiovascular Surgery 12-ft (3.7 m) re-usable sensor to monitor cable. Finally, during continuous processing, it is imperative that all data from the sensors be transmitted in real time to higher-level control systems and to data historians. But digital communication protocols are becoming increasingly popular as production facilities continue to grow more sophisticated. PendoTECHs Single Use Pressure Sensors measure static and dynamic pressure of gases and liquids in your biopharmaceutical processes accurately and cost effectively. Our nationwide service facilities deliver technical support, preventative maintenance, calibration and fast repairs. Equipments, Analytical Instrumentation / Analytical Equipment, Medical Equipment Sterilization Equipments, Blood Transfusion, Dialysis and Extracorporeal Circulation Equipments, Medical Examination and Monitoring Equipments, Respiration, Anesthesia and First Aid Equipments, Obstetrics and Gynecology, Assisted Reproduction, Contraceptive Devices, Neuro and Cardiovascular Surgery Instruments, Infusion, Nursing and Protective Equipments, Non-Active Implantable Medical Device Testing, Active Implantable Medical Device Testing, Implantation with Histopathology Tests (ISO 10993-6 & ISO 10993-12), Risk Assessments (ISO 10993-1 & ISO 10993-17 & ISO 14971), Subacute & Subchronic Toxicity (ISO 10993), Acute Systemic Toxicity & Pyrogenicity (ISO 10993-11 & ISO 10993-12), Biocompatibility Evaluation of Breathing Gas Pathways in Medical Devices (ISO 18562), Material Characterization Screens of Raw Materials, Medical Device Biological Indicator-Sterility Testing, Biological Indicator-Population Verification, Microbial Identifications & Strain Typing, Rapid Endotoxin Testing for Medical Devices, Electromagnetic Compatibility (EMC) Testing, Transportation and Distribution Simulation Studies, Medical Devices Single Audit Program (US, AUS, BR, CAN & JPN), Protective Barriers & Material Performance, Bacterial & Viral Filtration Efficacy (BFE/VFE) Test, Partible Filtration Efficiency (PFE) Test. The seller will arrange the return pick up for these items. The increased resolution of the PMAT-HR by 10-fold over the standard monitor reduces the error of a low-pressure process measurement and improves its capability for leak testing in single-use sensors. Another challenge of incorporating single-use sensors into a GMP process is the closed nature of the bioprocess system and associated single-use manifold. As this photo indicates, these sensors are available in a range of sizes. HW$82X&saF9##-=5|=i/nt/Eq/'=g=v^.ez:k=M These sensors use PendoTECH high-precision pressure (MEMS-HAP ) chips that are ideal for filtration and chromatography processes, glass and disposable Bioreactor monitoring, filling operations, etc. Tel: +1-609-799-2299 Copyright 2018 PendoTECH PTSS-REV3 PendoTECH PressureMATTM Sensor TransmitterThe PendoTECH PressureMATTM Sensor Transmitter connects to the PendoTECH Pressure Sensor and produces a 4-20 milliamp signal that is linear with pressure. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. - If your return is due to an Amazon error you'll receive a full refund, else the shipping charges (onward & return) along with import fees will be deducted from your refund amount. These items are not eligible for self-return. XPRT, Biological Oxygen Demand (BOD) Monitoring, (please review Application Note- Autoclave of Single Use Pressure Sensors), PendoTECH - Single Use Pressure Sensors - Brochure, Applications include multi-stage depth filtration, TFF/crossflow filtration, and bioreactor pressure monitoring and many more, Available for use with tubing from 1/8 inch to 1 inch inner diameter (for luer size see below) or a sanitary flange, Unobstructed flow path & no dead legs provides dramatically reduced hold-up volume versus stainless steel transducers or gauges, Qualified for use in the range from -7 to 75 psi, Integral 12 inch cable connects to reusable monitor/ transmitter/alarm cable via molded connector, Each sensor is tested for quality and accuracy during manufacturing and rejected if out of specification (no calibration required), Manufactured in a clean room in an FDA registered, ISO 13485 facility, Polycarbonate material or caustic resistant polysulfone, Certificate of quality included with lot certification; individual NIST Calibration Certificates are optional, May be non-invasively tested in-place with the PressureCHECKER device, PDKT-650-298SC Reusable shielded 6 ft connector cable w/ phone jack for Scilog pumps, PDKT-650-298MG Reusable shielded 6 ft connector cable w/phone jack for Midgee monitor, PDKT-650-298MN Reusable shielded 6 ft connector cable w/ phone jack for Pall Minim, PDKT-103-03 1/4 inch x 1/4 inch polycarbonate straight connector with luer port, PDKT-104-03 3/8 inch x 3/8 inch polycarbonate straight connector with luer port, PDKT-105-03 1/2 inch x 1/2 inch polycarbonate straight connector with luer port, PDKT-V3PS-000 Luer polysulphone 3-way stopcock. They are available in corrosion-resistant polysulfone to withstand the disinfection process. This version is the high-resolution (HR) model. PendoTech Single-Use Pressure Sensor, Sterile, Polycarbonate, Luer Fitting, Proudly Supporting Science and Technology in Australia Since 1952. There was a problem adding this item to Cart. Please refresh and try again. Keep up to date with our latest product demonstrations, webinars and exhibitions. Copyright 2022 STEMart. Pressure sensors feature a max pressure for 75 psi, with the DPG monitor having an accuracy rating of up to 30 psi. We encountered an error while updating this page. The design features no mold parting-line where the tubing is secured, which can be a source of leaks. PendoTECH Single Use Pressure Sensor Overview- Video, PendoTECHs Single Use Pressure Sensors measure static and dynamic pressure of gases and liquids in your biopharmaceutical processes accurately and cost effectively. turbidity

PendoTECH also conducted studies to demonstrate the accuracy of its PressureMAT-SHR model. There was a problem completing your request. Dennis C. Annarelli Ph.D. Technical Manager PendoTECH The accuracy specification of the sensors is 2% of reading plus the 0.003 psi ZOS. You can change out the sensor based on the tubing size you need to use in your line. Any use of PendoTECH single-use sensors for greater than 90 days should be evaluated by the end user before incorporating into their process. Sensor Type, Materials, and Accuracy, Single-Use Sensor: Materials of Construction, Sizes, and Technology. 2022 Masterflex, LLC.

PendoTECHs Single-Use Pressure Sensors measure static and dynamic pressure of gases and liquids in biopharmaceutical processes. The following article details extensive lab testing conducted by PendoTECH to demonstrate the reliability and performance of PendoTECH Single-Use Pressure Sensors over time. This rate value would go up or down proportionately with larger or smaller containers. Please make sure that you've entered a valid question. PendoTECH single-use sensors are accurate enough for sensitive applications, such as leak testing, and can be read locally as well as integrated into higher-level systems. - Once the package is received at Amazon Export Sales LLC fulfillment center in the US, it takes 2 (two) business days for the refund to be processed and 2- 4 business days for the refund amount to reflect in your account.

Overview of PendoTECHs Performance Tests. 1 0 obj<>/XObject<>/ProcSet[/PDF/Text/ImageC]/ExtGState<>/Properties<>/MC1<>>>>>>> endobj 2 0 obj<>stream And, relative to the single-use systems having a constant volume (V), a settling time should be considered before the final tare to achieve rigid position of the somewhat flexible components. Table 1. PendoTECH's Single Use Pressure Sensor accurately and economically measures static and kinetic pressures of gases and fluids in biopharmaceutical processes. If youve received a seller-fulfilled product in a condition that is damaged, defective or different from its description on the product detail page on Amazon.in, returns are subject to the seller's approval of the return. Sensors are single-use and suitable for gamma irradiation. Copyright 2022 Genetic Engineering & Biotechnology News. GEN Genetic Engineering and Biotechnology News, Supplement: Single-Use Pressure Sensors for Continuous Processing and Leak Testing, The growth of continuous processing in the, bioprocess industry is driving demand for sen, sors that can be used reliably for extended, periods of time with no degradation in sensor, performance. PendoTECH pressure sensors can be used for pressures up to 75 psi and can be used in conjunction with PendoTECH's PressureMAT monitor / transmitter, PendoTECH's process control system, or other monitors certified by third party. Monitors that have built-in transmission functions can be seamlessly integrated into existing plant architecture via analog or digital output signals. After 93 days exposure to 10 psi, the pressure sensors remained accurate. The data collected by these systems can be output to a PC or another data monitoring device. To address this requirement, PendoTECH developed a modified version of its PressureMAT (PMAT) monitor for single-use sensors. These pressure monitors are handheld, and battery operated for field use. For single-use sensors to be viable in a com, mercial continuous processing facility they, must be made of highly durable materials and be available in smaller sizes than sensors traditionally used in large batch processes. This feature can be used to test the communication chain from the monitor. Display to x. X psi with updates >2x per second (x. Xx upon request), Find answers in product info, Q&As, reviews. Finally, there is a full range 0-60 psi Transmitter available. Your recently viewed items and featured recommendations, Select the department you want to search in. Four options are available to deliver optimal performance based on pressure range. If a more secure fitting than a tie-wrap is required for higher pressure, either a BarbLock or Oetiker Clamp can be used, and they both give a very secure 360 radial compression seal. t>R8s>dM/A~=mv,k Standard Fluid Transfer Assembly Extension Set, 1/2 in. We couldn't find any matches. One-touch button for sensor tare at 0 psi. With the universal luer fitting, they can be adapted to processes in different manners. Tables C & D report the testing results after applying a known pressure/vacuum to each sensor from one lot exposed to both irradiation levels. You can also return the product within 10 days of delivery for full refund. Figure 1. Any use of PendoTECH single-use sensors for greater than 90 days should be evaluated by the end user before incorporating into their process. 1996-2022, Amazon.com, Inc. or its affiliates. DjamieKpryI8$?Zq@:+=A0US].7ABf+*)\]Ff$vHNq\)8J -Jcdk- q_hPYjy]bC*$l#+qHa"@Y\Sfgt&@MN=9@C:Z#S%! In addition to examining the impact of time and type of exposure of the sensor materials, during a continuous process of up to 90 days, the susceptibility of the sensor to measurement drift/change in calibration was examined. The pressure sensors can be integrated for pressure measurement and control with either a PressureMAT System (monitor/transmitter) or a PendoTECH Process Control System, depending on the number of sensors and process requirements. PendoTECH has developed a solution for each single-use sensor, and associated monitor, resulting in the claim of no calibration required at the point of use. Refunds are applicable only if determined that the item was not damaged while in your possession, or is not different from what was shipped to you. Generally, this manifold arrives presterilized, and thus calibration cannot be done at time of use without compromising the sterility of the system. This high-resolution monitor is specifically designed for very-low-pressure measurements. For seller-fulfilled items from Sports collectibles and Entertainment collectibles categories, the sellers need to be informed of the damage / defect within 10 days of delivery. To calculate the overall star rating and percentage breakdown by star, we dont use a simple average. The methods used to make this claim for single-use pressure sensors are shown in Table 1 under Built-In Accuracy Method.. A tie-wrap placed over the antirotation device (designed by Eldon James Corp.) will lock the tubing, preventing it from becoming loose by a twisting motion. Application: Multi-stage depth filtration, TFF/crossflow filtration, and bioreactor pressure monitoring. Single-use sensors and their associated monitors should have built-in communication protocols allowing for data to be transmitted, in real time, to higher-level control systems and data historians. No tare of the sensors was conducted post-exposure. You can edit your question or post anyway. To demonstrate the performance of PendoTECH single-use sensors over time, lab studies on PendoTECH single-use pressure sensors were carried out, demonstrating that the sensors maintain accuracy during periods of prolonged continuous use. Overall, the test results clearly show the PendoTECH single-use pressure sensors remain well within their stated accuracy specification over the life of the experiment. CS^&a k1*gG"EqL$.dkjj+IO-a^|K$j. Rare Mutations in CIDEB Gene Protect against Liver Disease, Peptide Promotes Nervous System Repair in Stroke Animal Models, Rifamycin-Resisting Trick Discovered in Bacteria, Ultrasound Sticker for Live Imaging of Organs in Moving Patients, Enzyme that Promotes Diet-Induced Obesity Could Point to Inhibitor Therapy, Outlining the Latest Regulatory Trends in Advanced Therapies, Like Cell and, Molecular Code for Lewis X Makes Glycosylation Controllable, COVID-19 Drives Surge in Growth of Single-use Technologies, Continuous Bioprocessing: Brave Old Challenges with Bold New Technologies, Visions of a Continuous Bioprocess Future, Continuous Processings Benefits within Biopharmas Reach, Vero Perfusion, Packed-Bed Vessels Intensify Vaccine Production, A Swiss Army Knife for Modern Biomanufacturing, Next-Generation Processing a Multidisciplinary Pursuit, Duchenne Muscular Dystrophy Mutation in Dogs Reversed by CRISPR-Cas9, Sports Supplement Inhibits Growth of Drug-Resistant Breast Tumors, Outlining the Latest Regulatory Trends in Advanced Therapies, Like Cell and Gene Therapy, Precision Medicine Looks beyond DNA Sequences. Masterflex Single-Use Systems and Assemblies, PendoTECH PressureMAT DPG Handheld Monitors, PendoTech PMAT-DPG Handheld PressureMAT Monitor for One Pressure Sensor, 0 to 6psi: +/- 2% of reading; 0 to 30 psi: +/- 3% of reading, Handheld PressureMAT Monitor for One Pressure Sensor, You have successfully subscribed to our newsletter, Add more products on the full Quick Order page, Gear and Positive Displacement Flowmeters, Masterflex Pump Head Roller Material Compatibility, MasterSelect Pump Configurator and Selection Tool, REACH 209 Statement, Jan 2021.pdf Literature, ROHS 3 Statement, Jan 2021.pdf Literature, Reads sensors to their specification of 0-6 psi +/- 2% of reading; 0-30 psi +/- 3% of reading, Battery operated - Uses 9V battery (approximate 14 hours of power), No calibration required when used with the pressure sensors (the standardized sensor output signal is read), One-touch button for sensor tare at 0 psi, Minimum / maximum pressure display buttons, Display to x.x psi with updates >2X per second (x.xx upon request). control system bioreactor soon coming