The weight of FREJA 300 is only 15, Electricity Meter in the age of Photovoltaic Avi Lugassi Introduction In this article we will learn how the electronic Energy Meter can deal with the massive penetration of renewable Photovoltaic energy, E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation, The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range, Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier, 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical, User s Manual Before using the inverter, you need to read and save the safety instructions. Measuring converter: optional association of an instantaneous parameter to one of the analogue outputs available ( ma / ma) measurement on inputs (TRMS) CT secondary 1 and 5 A 1 and 5 A Measurement range ka Input consumption <0.1 VA Measurement updating period 1 s Accuracy 0.2% full scale Impulse withstand voltage 4 kv Voltage measurement (TRMS) Direct measurement between phases VAC PT secondary 100VAC/ 400VAC 50 / 60 Hz Input consumption <0.1 VA Elctrical power measurement (V,I,P,Q) Accuracy 0.20% measurement Measurement range Hz Accuracy 0.10% Energy accuracy Active (according to IEC ) Class 1.0S Reactive ( according to IEC ) Class 2.0S Auxiliary power supply AC voltage DC/AC 85~265 30 % 50 / 60 Hz Consumption < 10 VA Outputs (pulsed) umber of relays 2 channel Coupler relay Outputs (analog) umber of outputs 1 channel Isolated Range 0 / ma Maximum current 30 ma Communication Link RS485 (2/3 wires half duplex) Protocol Modbus RTU mode MODBUS speed 4800/ 9600bauds Three phase electrical network power quality detection device, provide energy consumption and generate; THD (Total Harmonic Distortion); Harmonic individual data reading.

Intelligent power measurement system With power measurement system installed, your building must be in effective management of both energy and human resources. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm. Wide range of power supply AC80-450V. Main Automatically determine the connection phase Available the capacitor capacity, C / K value test Have Microprocessor, can set the switching mode: cycle switching, code switching and code set Independent testing each phase parameter, use "all-phase compensation" and "each-phase compensation" cross mode, successfully resolved the three-phase unbalanced compensation RS485 communication, MODBUS-RTU communication protocols Support maximum 16 route output, Various Application Lower energy consumption and costs. Main Class 0.2 or 0.5 power and energy measuring/5 or/1 A RS-485 MODBUS-RTU Communications Expandable input / output modules (up to 3 modules) ITF Technology: galvanic insulation protection inputs outputs. With self-heal design, prevent over-voltage damage, standard 400V/600V working voltage from 5KVAR to 30KVAR, accept customized specification order Rated output: 1~60Kvar Rated frequency: 60/50Hz.

With higher precision and more measurement parameters. Select from single and dual-channel models with AC, DC, or loop-powered operation. EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken, Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered, NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents 2 2 Glossary 3 SCADA3 3 NC-12 Modbus in general 3 4 Entire system 4 4.1 PFC to PC connection alternatives4 4.1.1, SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy, The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. Working Voltage 8.5VDC Measurement: Output signal types 4-20mA / 20-4mA Response Time < 1S (0-90%,100%-10%) Precision 0.05% Temp. 252 C Dimensions 113 X 109 X 17.5mm Terminal Wiring Way Screw Comm Interface Mini USB Standard E61326 : 1997+A1: 1998+A2 : 2001+A3 : 2003 LED Indicator ormally lighting indicates power supplied and working normally, blinking indicates digital communication is under way.

Support universal Input Signal Provide VDC input loop power TC/RTD sensor broken alarm Low Temp. powerlink panelboards -40 ~ 85 C / 95% RH Calibrating Ambient Temp. connected 110V, 230V, 240V, 400V, 415V ac +/-20% <1 VA voltage <0.2 VA current : 2 times continuous,30 times /1s. Product specifications will change from time to time. Measuring converter: optional association of an instantaneous parameter to one of the analogue outputs available ( ma / ma) AC grid transducer converts an ac voltage or current input into a load independent output signal. If need rated capacity more than 300Kvar or any other requirements, please contact Blue Jay s Sales team for detail design. With RS485 communication port, can control extra 3 sets CD-212 build Max 48 step control.

SIMATIC S7-1200. Lower transformer losses.

It can visually display voltage, current, power data and energy cumulative data. 96*48mm or 96*96mm panel size optional.

Power supply: Power Supply Consumption Measurement: Voltage Active power Energy masurement Precision Isolation: Insulation Resistor Communication port Digital Link Other: Ambient Temp. Input voltage range 2. Please reference to the label on product body! The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. BJ-SI Series ame 1 Input signal channel 2 Output signal channel 3 Input signal type Convert Accuracy Typical wiring Loop Powered AMP mv Optional Type 1: Only one channel input 2: Dual channel input 1: Only one channel output 2: Dual channel output A: 0(4)-20mA B: 0(4)-20mA (with out input loop powered) T: TC(K,E,S,B,R,J,T,); mv( mv); V(0-1V) R: RTD(PT100,PT200,PT500,PT1000,Cu50); R(0-400,0-4000) Blank: Universal Input Signal Probe Type Range Minimum range A/D accuracy Conversion Accuracy K -270~1372C 100C 0.3C 1C or 0.1% E -270~1000C 100C 0.25C 1C or 0.1% S -50~1768C 500C 1C 2C or 0.1% TC B 400~1820C 500C 2C 2C or 0.1% R -50~1768C 500C 1C 2C or 0.1% J -210~1200C 100C 0.25C 1C or 0.1% T -270~400C 100C 0.25C 1C or 0.1% -270~1300C 100C 0.4C 1C or 0.1% PT100 / PT200 RTD PT500 / PT ~850C 50C 0.15C 0.2C or 0.1% Cu50-50~150C 50C 0.2C 0.2C or 0.1% R / 0~400 10 0.12 0.1 or 0.1% 0~4000 100 1 1 or 0.1% mv / +80mV ~ -80mV 3mV 12uV 0.10% Volt / 0~1V 100mV 0.25mV 0.25mV or 0.1% Ampere / 0~20mA 5mA 8uV 8uA or 0.1% VOLT + RTD / R TC AUX 24VDC Output_ Output_1 P-33 P-34, 21 1 AUX 2 3 K1 4 5 K AO RS BJ-PR Series Motor Protector BJ-PR Series Motor Protector PR Motor protector Relay Ordering Information PR200 motor protector is an all-in-one solution designed to continuously monitor 3-phase power lines for abnormal conditions. INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series, ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw, User's Guide. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage. Voltage: 2 times continuous. 0.5class high-precision performance, can instead of your old analog indicator or digital single-function products such as ammeters, voltmeters or watt meters etc. With power measurement system installed, you can easily get the information how much energy consumption every day. Medium and low voltage systems. 252 C Dimensions 18mm x 10mm Terminal Wiring Way Soldering Comm Interface Double pins interfaces Convert Accuracy Type Full Span Min.

Salient Features : Application : Product Features: FREQUENCY TRANSDUCER, Energy Management Power Analyzer Type WM14-96 Basic Version, User Manual V1.0 2014 SDM220MODBUS. PAGE Chapter 1 General Information 1. with TCP/IP port, RS232/485 port even provide GPRS remote connection, allow user free to connect to local PC or WEB server.

50Hz, 60Hz 4~20mA, 0~5V, ( others on request) 0~20mA; 5~10V; 0~10V; Maximum load <750 (0-20mA, 4-20mA) >2000 (voltage output) R ipple <1% peak to peak R esponse time <250ms 0-90% <500ms 0-99% Measurment Accuracy Class 0.2 % / 0.5 %complying with IEC 688 Accurate range 0-120% I influence <0.02% per Hz Load influence <0.25% of full span for specific load range Auxiliary Supply 48V, 110V, 230/240V AC 20%, 1.5VA 24V, 48V, 110V DC 20% 2W Galvanic isolation between input, output circuits and auxiliary sup Test voltage 2KV RMS 50Hz for 1 minute impulse 4KV 1.2/ 50sec waveform Temperature requirements Operating -10~55C Storage -40~70C, 20 ~ 93%RH ; oncondensing AC programmable transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Built-in isolation circuitry can measure the maximum 1KV voltage signal. / Humi.

96*48mm panel size.

2-in-1 Design Concept One module now contains the functions previously only obtainable by combining, Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. By taking the self-healing type low voltage power capacitor as the main body, add the intelligent measuring and controlling processor as the control center, It can achieve zero-crossing control of thyristor, delay switching of contact of the mechanical type magnetic latching relay. With RS485 communication interface, 195DCE can be connected to the monitoring center. Provide 12 channels DI port, 2 channel DO for control. Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. tasco tms Isolated or on-isolated Input Voltage meter Meter P-19 P-20, 14 MTX series DC battery monitor MTX series DC battery monitor Automatic Power Factor Controller MTX100 is a new-type voltage meter which can measure voltage, current, power, charging capacity and time at the same time. Excellent temperature characteristic and good working stability. Power Meter Series 800.

Application : The RISH CON - Hz transducer is used for frequency measurement. Substation Maintenance and Commissioning Test Equipment, 1.44 kw Programmable DC Power Supplies XLN Series, Automation System TROVIS 6400 TROVIS 6493 Compact Controller, FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1, TURBOtech srl. 252 C Dimensions 45mm x 20mm Terminal Wiring Way Screw Comm Interface Double pins interfaces P-55 P-56, 32 MICO-RACE Wireless Temperature monitor MICO-RACE Wireless Temperature monitor MICO-RACE Typical applications MICO-RACE wireless temperature measurement system uses advanced cloud technology, temperature data collected by each sensor from Ethernet or 3G router, and transfer to the cloud platform, and data management through highly reliable cloud servers. Application Metering of distribution feeders, transformers, generators, capacitor banks and motors.

Free to set the single phase/three-phase capacitor control step, with smart switching control, identifies the power of the connected capacitor stages and connects or disconnects them in an optimized manner as required by the actual mains conditions. ocean underwater science futuristic magazine hal clement edition 1967 pdf arthur ituner 12V/6.6A SERIES NO. Delivering Solutions for Energy Management, Temperature & Humidity SMS Alert Controller, Zlinx Wireless I/O.

Wireless temperature monitor system The wireless temperature monitoring system is a completely customizable monitoring display and alarm system for temperature critical applications. The TDB series Automatic PFC is for low voltage design, standard for Three phase 400VAC power line; if need 600VAC type please contact Blue Jay s Sales team.

Designed to satisfy, devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2, CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter, SL Series AC and DC Electronic Loads Applications AC & DC Power Supply Testing Rechargeable batteries and chargers Fuel cell test - cells and stacks PFC circuit test Pulsed LED Test and Burn-in Laser Diode, IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration, CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction. 3 Specifications 4 Installation5. JNIOR Model 312.

Multi-use LED screen for volt / amp / energy data. functions as both basic I/O for integration with another application or system AND as a, Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power, Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. The output device will then control the temperature variation within a specific range. Class 0.5S power and energy measuring/5 or/1 A Backlit LCD display Expandable input / output modules (up to 3 modules) With RS-485 Modbus/RTU Communications With 2 channel Pulse Output (PO) for active energy&reactive energy counting Optional 1 channel Analog Output (AO) Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO) Record and read multi- tariffs ratio, Up to 3 months ITF Technology: galvanic insulation protection inputs outputs Universal series power supply (85-265VAC/DC) Application Applied to the control of general switch boards and low, medium and high voltage connection points. de la Gare - 95100 ARGENTEUIL Tl : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -, SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. Application. 3 3.

Rated voltage: 220VAC~690VAC, Excellent self-healing performance Lower Power Bills / Improved Power factor Lower Stress Heavy Duty Designs Available Increased durability and tolerance of harmonics and transients Single phase/three phase electrical capacitors for power factor correction Temperature-25+50,humidity 85%RH,and altitude lower than 2000m Rated voltage Over voltage HY /450/525/690VAC 1.1Un(last 8 hours/day), 1.3Un(last 1 min) BSMJ 250/400/450/525/690/750/ 1050VAC 1.1Un Over current Max 1.3In Max 1.3In Surge current tolerance 200In 200In Power consumption <0.25W/kvar <0.25W/kvar Test voltage, terminal to terminal 2.15Un, 10s 2.15Un, 10s Test voltage, Un<660V: 3000VAC, 10s terminal to shall Un>660V: 6000VAC, 10s 3000VAC, 10s Cooling method Life time 100,000hours Air-cooled 100,000hours Shell material Stamping aluminum cans Stamping aluminum cans Install mode M12/M15 nuts fix on the M12/M15 nuts fix on the shall button shall button Discharge resistor External connect Internal connect, Residual voltage decline to 75V after power off 3min Standards IEC IEC Detail information for capacitor ordering, please contact Blue Jay sales team The BA series intelligent combination type low voltage power capacitor, it has microelectronic software and hardware technologies inside. This helps in increasing the life of equipment and reducing the load of generator. Display. Models. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement.

directional positions monoblock prince flash sorry player SED-635 Digital Excitation System. Use semi-solid impregnant, no oil leakage, is a new generation of environmentally friendly products. The device is widely applied to low voltage reactive power compensation device to replace the subassembly composed of three XD1 current-limiting reactors and CJ10 contactor, and it is also can be used in the general control circuit to limit surge impact, protect capacitor and other electrical device from over voltage damage. 3.Have special requirements, please contact Blue Jay Technical Support Team: P-31 P-32, 20 SI series Signal Isolator SI series Signal Isolator SIXX Signal Isolator DI-Rail Mounrting Blue Jay Technology offers the industry's best selection of isolators. It is a high-performance automatic meter suitable for industrial and mining enterprises, civil construction, building automation. Protection of the parameters of programming by password. Power supply: Standard 85~265VAC 50/60Hz Optional 24/48DC Power consumption <5VA Input signal: Input signal channel Max 2 channels Temperature sensor TC (-20~99C) or customer request Humidity sensor Digital type (0~99RH) or customer request Sampling ratio 400ms Control output port: Output channel Max 2 channels Relay 250VAC, 5A (10A optional) Other port: Linear output DC 4~20mA/0~5V optional Alarm output Passive nodes Communication output RS-485 MODBUS RTU, 4800/9600bauds Other output port: IP protect 40 Isolation: Test voltage Ambient temperature: Operating Storage Galvanic isolation between input, output circuits and auxiliary supply 1.5KV RMS 50 Hz for 1 minute -10~55C -40~70C, 20 ~ 93%RH ; o condensing P-51 P-52, 30 Temperature Humidity Temperature Humidity S series Temperature Controller S series Temperature Controller Ordering Information BJ W 3 S Install Dimensions Front view Side view Rear view Fix Frame Wiring pin 55mm Unit: mm Series ame 1 series code 2 panel size 3 temperature signal in 4 humidity signal in 5 control output 6 linear output 7 communication port 8 sensor type Optional Type S: Intellegent type (two lines LED screen) B: dial plate control type G: fixed control type (without screen) 42: For 72(W)x72(H)x96(D)mm Blank: standard 48(W)x48(H)x90(D)mm 1: one channel temperature sensor input 2: two channel temperature sensor input 1: one channel humidity sensor input 2: two channel humidity sensor input K1: one channel output K2: two channel output Kx: special for customerized DA: one channel 4~20mA linear output DV: one channel 0~5V linear output Blank: without this function R: one channel RS-485 communication port Blank: without this function Blank: TC sensor(0.2% accuracy) T: thermocouple (K,J,T,E,,R,S,B,L,U,YXK) P: platinum RTD (PT100) L: linear signal (0~5V, 0~10V, 0~20mA, 4~20mA, 0~50mV) Relay 1 Relay 2 Alarm C %RH Menu 48mm 55mm C %RH Menu 48mm 72mm Menu C C Alarm Temperature Power C 48mm 48mm 78mm 78mm 66mm 45mm 35mm DI rail 6 7 Din-rail module mm mm otes: 1. 2. c. Accuracy PT100 PT C RTD PT500 50C 0.05C 0.1C / 0.05% PT1000 Cu C Resistor / 0.05 0.1 / 0.05% 0.5 1 / 0.05% otes: The 0.x% is a relative accuracy based on full span. Balance load phase compensation type Provide current, voltage, COS measurement and display 93*70mm LCD display screen Support max 16 control channel (default 12 channel) Users free to configure single phase/three phase capacitor control channel Anti-harmonic design, can protect capacitor in high harmonic transient DC12V thyristor output Rapid response time<100ms RS485 port optional Measurement Accuracy Volt, Amp, PF, 0.5 class Active/Reactive power 1.0 class Main control setting Turn-on Threshold 0.90 ~ 0.99 continuously adjustable Turn-off Threshold -1.0 ~ continuously adjustable Delay time of switching output 10s ~ 120s Over-voltage protective setting %Ue adjustable and 5v hysteresis Under-current lock value %Ie adjustable and 1.5%Ie hysteresis Capacitor Switching Capacity Dynamic output 50mA,12VDC Dynamic response <20ms Auxiliary Supply R ated Voltage 415V AC (-20% ~ +10%), 50Hz10% R ated sampling 0 ~ 5A /<0.1 50HZ (60HZ option) Power consumption <10W Insulation protection Test Voltage 2.5 kv RMS 50 Hz,1min Inputs & Case Protection Class o less than IP 40 Over-voltage breaking time <1.5min Operation conditions Working Temperature 0 to +60 deg C Storage Temperature -30 to +65 deg C R elative humidity < 85% BJ-C Series Ordering Information DISPLAY MODEL Standard with this function Function optional - Without this function BJ Series ame 1 series code Optional Type CA: 3P3W Basic power factor controller (CAY for LCD display) CB: 3P3W Advanced power factor controller 2 control step 4, 6, 8, 10, 12, 16 steps optional 3 control mode 4 special function 5 voltage level CA212 CB212 CD-212 CF212 3 digital LED LCD display METERIG FEATURES Power factor display /voltage/ display - Active/reactive power display - SWITCHIG FEATURES 6 step output - 12 step output - 16 step output - Step status display Anti-harmonic distortion(thd) - R apid response(<20ms) / / / COMPESATIO FEATURES Balance load compensation - Unbalanc load compensation Single-phase compensation - - COMMUICATIO PORT R S485 MODBUS-RTU - CD: 3P3W Advanced power factor controller/compatible with single-phase CF: 3P4W Power factor controller J: 5A/250V AC contactor control D: 12VDC Static contactor control Blank: without this function R: RS485 communication Blank: 415V 50Hz standard (30% tolerance) Special requirement show the P- voltage otes: 1.